    Storage tanks in parallel

    Hi,

    I have recently replaced two existing storage tanks due to a bladder failure on one with similar tanks (Flotec Model 7130-08 Equivelent Std Tank 220 Gallon).

    These tanks are in parallel off the well and my problem is only one tank is filling, the one furtherest from the tee. The other tank stays empty. I checked the pressure on the empty tank (shut off the valve to the full tank first) and read in excess of 50 lbs pressure on the empty tank (high as the tire guage would go). I bled off a large amount of air and then I shut off the well and opened a faucet. When the pressure gauge on the well reached 30 lbs (and water still coming out of the faucet) I further bled the empty tank to ~ 25lbs and restarted the well. Water appeared to now fill this tank. At 60 lbs the pump stopped and I checked the pressure on the this storage tank and it was ~45 lbs. I opened the valve on t he first tank and there appeared to be some minor balancing and the pressure on the well dropped ~10 lbs to 50 PSI.

    The pressure switch on the pump is set at 40/60 and it working as expected based on the pressure gauge. How do I get this set up right???

    Thanks,

    Dave

  2. #2
    Pump guy speedbump's Avatar
    Join Date
    Jun 2005
    Location
    Murphy, NC. USA.
    Posts
    11,786
    Get ready to change those tanks again in about 1.5 years. That seems to be their life expectancy.

    To read how to set them up, follow the link at the bottom of this post.

    bob...


    Frequently asked questions at a glance.

    Return to Pumps & Tanks

  3. #3
    Thanks. I did read the link earlier. Not clear if both tanks should be set the same (38 PSI). That was the way they were set and the one tank would not fill.

    Pressure switch and both tanks are well within Flotec recommendation of 10 feet.

  4. #4
    Pump guy speedbump's Avatar
    Join Date
    Jun 2005
    Location
    Murphy, NC. USA.
    Posts
    11,786
    They should both fill equally if the air pressure is the same in both. You did check the air with the pump off and all pressure off the system > rite?

    Unless you are using an extremely small pipe to feet these tanks, they should fill the same. Just set the air pressure the same in both.

    bob...


    Frequently asked questions at a glance.

    Return to Pumps & Tanks

  5. #5
    Thanks Bob.

    Yes, the pressure was off both. I'll play a little more with it tonight.

    Dave

    BTW, what brand of tank do you recommend?

  6. #6
    Pump guy speedbump's Avatar
    Join Date
    Jun 2005
    Location
    Murphy, NC. USA.
    Posts
    11,786
    Flexcon or Well X Trol. I sell the Flexcon and love them.

    bob...


    Frequently asked questions at a glance.

    Return to Pumps & Tanks

  7. #7
    Senior Member
    Join Date
    Jun 2005
    Location
    Wherever we park the motorhome, , USA.
    Posts
    569
    I always drain the water out of the tank, tank manufacturers say to, otherwise you get the pressure you are setting it at but not the correct volume in the tank...

    Gary
    Quality Water Associates
    www.qualitywaterassociates.com
    Softener Forum: http://www.qualitywaterassociates.com/phpBB2/index.php

Thread Information

Users Browsing this Thread

There are currently 1 users browsing this thread. (0 members and 1 guests)

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •