    CSV sizing room to grow- wiring

    Have a submersible pump (Lancaster) running 110V 1/2 hp. Well is about 500 feet deep and gives plenty of water. 60 year old well. Pump down about 125+ feet.
    Have a 25 gal. bladder tank, currently a 30-50 pressure switch. 1" black plastic pipe to the house. There are only the two of us in the house.

    Eventually I will probably go to a 220V 1/2 to 3/4 HP pump. I plan on moving the tank, switch etc from the field it is in to next to the house, about 600 feet away. Want to increase the pressure switch to a 40-60.

    2 questions, can I use the same wire used down the well all the way to the house in 1" electrical PVC conduit? Will it carry the load? I would like one continuous run of wire. It is the standard yellow pump wire.

    Secondly what size CSV would I need now and would it do for the future. I can change the pressure switch now if needed.


  2. #2
    Pump guy speedbump's Avatar
    Join Date
    Jun 2005
    Location
    Murphy, NC. USA.
    Posts
    11,786
    If you want to buy a preset valve in either 40, 50 or 60 psi. you would need the CSV1/??. If you want to play with the valve and set your own pressure, the CSV1W or CSV1Z would be the choice. The presets are plastic and the others are bronze.

    PS: I got a notification that you tried to send a Private Message. The Forum won't allow this to happen until you have make 10 posts or more. It is nothing against our members, it's just spam prevention.