https://terrylove.com/forums/index.p...use-run.85135/


You can put the pressure tank and pressure switch at the well head or at the house with proper size pipe. Not having proper pipe size before the pressure tank and pressure switch at the house on the long pipe run will have big pressure drops(friction loss)back feeding to the water yard hydrants from the "pressure tank" feeding to the hydrants(already posted that problem from DIY or plumber mistake).

Your pressure tank feeds your flow and pressure before the pump maintains your flow and pressure. Irrigation systems and residential systems that have low flow rates are better handled with a cycling system over the years!